An objective methodology for evaluating the mechanical compliance of osteotomy preparations: Part 1 - Final report project "Tools, Technology, Research for implant placement with guided system"

Authors: B. Truyen, C. Boca and J. Cornelis

Publisher: ETRO-IRIS Research Group, Faculty of Engineering, Vrije Universiteit Brussel, Belgium

Publication Date: Dec. 2009


Abstract:

Extensive trauma during the osteotomy preparation is considered a major cause of implant failure because thermal as well as mechanical factors contribute to the formation of necrotic tissue, thereby affecting implant stability. Thermonecrosis, resulting from the frictional heat generated during implant surgery is known to compromise severely bone regeneration. In an extensive literature, differences in heat generation were related to multiple factors, including drill design, drill loading, rotational speed, drill wear, preparation depth, continuous versus intermittent drilling, and the use of graded implant drills. Another aspect, that received comparatively little attention, is the impact of the drill design and material composition on the mechanical tolerances of the osteotomy preparation. Especially when preparations are performed on angulated surfaces, oblique loading forces are developed that tend to bend the implant drill, which will not only affect the orientation, but also the shape and volume of the excavation volume. Undue loss of bone material as a result of drill bending directly compromises the primary implant stability, while deviations in the orientation may impede the accuracy of the implant planning. Drill wandering and vibrations during the initial seating of the implant drill into the cortical bone, often caused by blunting or an inappropriate drill design, may also contribute to an enlargement of the osteotomy volume. The aim of this in vitro study was to compare 3 commercially available stainless steel implant drills (Ankylos, Nobel Biocare, Straumann) and a newly released zirconium oxide implant drill system (2Ingis) for the effects of oblique drill loading on the mechanical specifications of the osteotomy preparation. To this end, an objective methodology was developed to quantitatively evaluate the mechanical compliance of osteotomy preparations, based on a combination of X-ray Micro Computed Tomography (XMCT) imaging and a mathematical modeling.

Other Reference Styles
Current ETRO Authors

  Bart Truyen

+32 (0)02 629 395

btruyen@etrovub.be

more info

  Cristina Boca

+32 (0)02 629 395

cboca@etrovub.be

more info

Prof. Dr. Ir. Jan Cornelis

+32 (0)02 629 293

jpcornel@etrovub.be

more info

Other Publications

• Journal publications

IRIS • LAMI • AVSP

• Conference publications

IRIS • LAMI • AVSP

• Book publications

IRIS • LAMI • AVSP

• Reports

IRIS • LAMI • AVSP

• Laymen publications

IRIS • LAMI • AVSP

• PhD Theses

Search ETRO Publications

Author:

Keyword:  

Type:








- Contact person

- IRIS

- AVSP

- LAMI

- Contact person

- Thesis proposals

- ETRO Courses

- Contact person

- Spin-offs

- Know How

- Journals

- Conferences

- Books

- Vacancies

- News

- Events

- Press

Contact

ETRO Department

info@etro.vub.ac.be

Tel: +32 2 629 29 30

©2024 • Vrije Universiteit Brussel • ETRO Dept. • Pleinlaan 2 • 1050 Brussels • Tel: +32 2 629 2930 (secretariat) • Fax: +32 2 629 2883 • WebmasterDisclaimer